Public Fields

  Name Description
Public field AnalyteName Array containing the names of 4 possible analytes. (inherited from ScanMethod)
Public field BiPotCR Specifies the current range for WE2. (inherited from Method)
Public field BiPotPotential Specifies the potential for WE2. (inherited from Method)
Public field BlankType Blank subtraction can be performed in two ways.

The blank can be measured using a separate blank solution.

The second curve is subtracted from the original curve.

(inherited from ScanMethod)
Public field CellOnAfterMeasurement Enable/disable cell after measurement (inherited from Method)
Public field CellVolume Is required to correct for dilution effect due to the addition of the standard solutions and to calculate the concentration in the original sample. (inherited from ScanMethod)
Public field ConcentrationUnit The label for the unit of the analyte's concentration. This value is not used for calculations. (inherited from Method)
Public field ConditioningPotential Conditioning Potential (inherited from Method)
Public field ConditioningTime Conditioning Duration (inherited from Method)
Public field DepositionPotential Deposition Potential (inherited from Method)
Public field DepositionTime Deposition Duration (inherited from Method)
Public field Determination StandardAddition requires measurement of the sample and a sample to which standard solution is added. Analysis by using Calibration curve requires a calibration curve. (inherited from ScanMethod)
Public field EndPotential Potential where measurement stops.
Public field EPeaks Specifies the expected peak potential. (inherited from ScanMethod)
Public field EPretreat Pretreatment potentials. (inherited from ScanMethod)
Public field EquilibrationTime Duration (inherited from Method)
Public field Istrip Stripping current.
Public field MeasurementTime Measurement Time
Public field MinPeakHeight Determines the minimum peak height. Peaks lower than this value are neglected. (inherited from Method)
Public field MinPeakWidth Determines the minimum peak width. Peaks width a lower width may not be detected. (inherited from Method)
Public field MuxMethod Defines the way the multiplexer is used.
  • 0 = measure channels sequentially
  • 1 = measure channels alternatingly
(inherited from Method)
Public field PeakOverlap Is used when two peaks are very close to each other. If the peak separation is less than the specified value, a single baseline is used for the two overlapping peaks. If each peak should have its own baseline, specify a value of 0. (inherited from Method)
Public field PeakWindow Is used to identify which component corresponds to which peak. Peaks must be within the peak window. (inherited from Method)
Public field Ranging Ranging information (inherited from Method)
Public field RecordAux Auxiliary channel to record (inherited from Method)
Public field Sample Description of the measured sample. (inherited from Method)
Public field SampleVolume Is used to calculate the concentration in the original sample from the peak height measured in the solution specified in the box of the cell volume. (inherited from ScanMethod)
Public field Sensor Description of the sensor used. (inherited from Method)
Public field SmoothLevel The smoothlevel to be used.
  • 0 = no smooth
  • 1 = 5 points
  • 2 = 9 points
  • 3 = 15 points
  • 4 = 24 points
(inherited from Method)
Public field SolutionNr Array containing the of 4 possible solutions. (inherited from ScanMethod)
Public field StandardConcentration Specifies the concentration given in 'Unit of concentration' of the component in the corresponding standard solution. (inherited from ScanMethod)
Public field StandardsValues If ConcentrationsAddedToSample is used, the specified values are used and peaks are not corrected. If VolumesAddedToCell is used, peaks are corrected for dilution due to the addition of standard solutions. (inherited from ScanMethod)
Public field StandbyPotential Stand by Potential (inherited from Method)
Public field StrippingCurrentRange Current range during stripping
Public field tPretreat Time applied for each potential. (inherited from ScanMethod)
Public field UseMuxChannel Specifies channels used for this method. (inherited from Method)
Public field UseStirrer True if a stirrer is being used. (inherited from Method)
Public field ViewBottom The lowest value on the Y axis of the plot. (inherited from Method)
Public field ViewLeft The lowest value on the X axis of the plot. (inherited from Method)
Public field ViewRight The highest value on the X axis of the plot. (inherited from Method)
Public field ViewTop The highest value on the Y axis of the plot. (inherited from Method)
Public field VolumeConcentration This table is used to specify either the added volume of the standard additions or the concentration of a standard solution. (inherited from ScanMethod)
Public field XUnit Unit for X axis when using this method. (inherited from Method)
Public field YUnit Default unit for Y axis when using this method. (inherited from Method)