Public Fields
| Name | Description | |
|---|---|---|
|
AnalyteName | Array containing the names of 4 possible analytes. (inherited from ScanMethod) |
|
BiPotCR | Specifies the current range for WE2. (inherited from Method) |
|
BiPotPotential | Specifies the potential for WE2. (inherited from Method) |
|
BlankType | Blank subtraction can be performed in two ways. The blank can be measured using a separate blank solution. The second curve is subtracted from the original curve. (inherited from ScanMethod) |
|
CellOnAfterMeasurement | Enable/disable cell after measurement (inherited from Method) |
|
CellVolume | Is required to correct for dilution effect due to the addition of the standard solutions and to calculate the concentration in the original sample. (inherited from ScanMethod) |
|
ConcentrationUnit | The label for the unit of the analyte's concentration. This value is not used for calculations. (inherited from Method) |
|
ConditioningPotential | Conditioning Potential (inherited from Method) |
|
ConditioningTime | Conditioning Duration (inherited from Method) |
|
DepositionPotential | Deposition Potential (inherited from Method) |
|
DepositionTime | Deposition Duration (inherited from Method) |
|
Determination |
requires measurement of the sample and a sample to which standard solution is added. Analysis by using curve requires a calibration curve. (inherited from ScanMethod) |
|
EndPotential | Potential where measurement stops, is in potential where scandirection reverses. (inherited from PotentialMethod) |
|
EPeaks | Specifies the expected peak potential. (inherited from ScanMethod) |
|
EPretreat | Pretreatment potentials. (inherited from ScanMethod) |
|
EquilibrationTime | Duration (inherited from Method) |
|
MinPeakHeight | Determines the minimum peak height. Peaks lower than this value are neglected. (inherited from Method) |
|
MinPeakWidth | Determines the minimum peak width. Peaks width a lower width may not be detected. (inherited from Method) |
|
MuxMethod | Defines the way the multiplexer is used.
|
|
PeakOverlap | Is used when two peaks are very close to each other. If the peak separation is less than the specified value, a single baseline is used for the two overlapping peaks. If each peak should have its own baseline, specify a value of 0. (inherited from Method) |
|
PeakWindow | Is used to identify which component corresponds to which peak. Peaks must be within the peak window. (inherited from Method) |
|
Ranging | Ranging information (inherited from Method) |
|
RecordAux | Auxiliary channel to record (inherited from Method) |
|
Sample | Description of the measured sample. (inherited from Method) |
|
SampleVolume | Is used to calculate the concentration in the original sample from the peak height measured in the solution specified in the box of the cell volume. (inherited from ScanMethod) |
|
Scanrate | The applied scan rate. |
|
Sensor | Description of the sensor used. (inherited from Method) |
|
SmoothLevel | The smoothlevel to be used.
|
|
SolutionNr | Array containing the of 4 possible solutions. (inherited from ScanMethod) |
|
StandardConcentration | Specifies the concentration given in 'Unit of concentration' of the component in the corresponding standard solution. (inherited from ScanMethod) |
|
StandardsValues | If is used, the specified values are used and peaks are not corrected. If is used, peaks are corrected for dilution due to the addition of standard solutions. (inherited from ScanMethod) |
|
StandbyPotential | Stand by Potential (inherited from Method) |
|
StepPotential | Step potential. (inherited from PotentialMethod) |
|
tPretreat | Time applied for each potential. (inherited from ScanMethod) |
|
UseMuxChannel | Specifies channels used for this method. (inherited from Method) |
|
UseStirrer | True if a stirrer is being used. (inherited from Method) |
|
ViewBottom | The lowest value on the Y axis of the plot. (inherited from Method) |
|
ViewLeft | The lowest value on the X axis of the plot. (inherited from Method) |
|
ViewRight | The highest value on the X axis of the plot. (inherited from Method) |
|
ViewTop | The highest value on the Y axis of the plot. (inherited from Method) |
|
VolumeConcentration | This table is used to specify either the added volume of the standard additions or the concentration of a standard solution. (inherited from ScanMethod) |
|
XUnit | Unit for X axis when using this method. (inherited from Method) |
|
YUnit | Default unit for Y axis when using this method. (inherited from Method) |