Name |
Description |
|
AnalyteName
|
The name of the measured analyte. (inherited from TimeMethod) |
|
BiPotCR
|
Specifies the current range for WE2. (inherited from Method) |
|
BiPotPotential
|
Specifies the potential for WE2. (inherited from Method) |
|
CellOnAfterMeasurement
|
Enable/disable cell after measurement (inherited from Method) |
|
ConcentrationUnit
|
The label for the unit of the analyte's concentration. This value is not used for calculations. (inherited from Method) |
|
ConditioningPotential
|
Conditioning Potential (inherited from Method) |
|
ConditioningTime
|
Conditioning Duration (inherited from Method) |
|
Current
|
Current during measurement (Potentiometry). The applicable range of the potential is -2 to +2 * current range. |
|
DepositionPotential
|
Deposition Potential (inherited from Method) |
|
DepositionTime
|
Deposition Duration (inherited from Method) |
|
EquilibrationTime
|
Duration (inherited from Method) |
|
IntervalTime
|
Time between two measurements. (inherited from TimeMethod) |
|
MinPeakHeight
|
Determines the minimum peak height. Peaks lower than this value are neglected. (inherited from Method) |
|
MinPeakWidth
|
Determines the minimum peak width. Peaks width a lower width may not be detected. (inherited from Method) |
|
mux_delay
|
Delay before switching to the next multiplexer channel. |
|
MuxMethod
|
Defines the way the multiplexer is used. - 0 = measure channels sequentially
- 1 = measure channels alternatingly
(inherited from Method) |
|
PeakOverlap
|
Is used when two peaks are very close to each other. If the peak separation is less than the specified value, a single baseline is used for the two overlapping peaks. If each peak should have its own baseline, specify a value of 0. (inherited from Method) |
|
PeakWindow
|
Is used to identify which component corresponds to which peak. Peaks must be within the peak window. (inherited from Method) |
|
Potential
|
Potential during measurement (AmperometricDetection) or applied before pulse is given PulsedAmpDetection. The applicable range of the potential is -2 V to +2 V. (inherited from TimeMethod) |
|
Ranging
|
Ranging information (inherited from Method) |
|
Reaction
|
Defines the type of reaction, used for analysis - 1 = Reduction
- 2 = Oxidation
(inherited from TimeMethod) |
|
RecordAux
|
Auxiliary channel to record (inherited from Method) |
|
Replications
|
Number of replications (inherited from TimeMethod) |
|
Sample
|
Description of the measured sample. (inherited from Method) |
|
Sensor
|
Description of the sensor used. (inherited from Method) |
|
Signal
|
If dc-current is specified, stationary dc-levels are searched. Specify 'Peak' when the current versus time plots will show peaks. (inherited from TimeMethod) |
|
SmoothLevel
|
The smoothlevel to be used. - 0 = no smooth
- 1 = 5 points
- 2 = 9 points
- 3 = 15 points
- 4 = 24 points
(inherited from Method) |
|
Standard
|
The concentrations of the analyte, used for analysis. (inherited from TimeMethod) |
|
StandbyPotential
|
Stand by Potential (inherited from Method) |
|
UseMuxChannel
|
Specifies channels used for this method. (inherited from Method) |
|
UseStirrer
|
True if a stirrer is being used. (inherited from Method) |
|
ViewBottom
|
The lowest value on the Y axis of the plot. (inherited from Method) |
|
ViewLeft
|
The lowest value on the X axis of the plot. (inherited from Method) |
|
ViewRight
|
The highest value on the X axis of the plot. (inherited from Method) |
|
ViewTop
|
The highest value on the Y axis of the plot. (inherited from Method) |
|
XUnit
|
Unit for X axis when using this method. (inherited from Method) |
|
YUnit
|
Default unit for Y axis when using this method. (inherited from Method) |