Public Fields

  Name Description
Public field AnalyteName The name of the measured analyte. (inherited from TimeMethod)
Public field BiPotCR Specifies the current range for WE2. (inherited from Method)
Public field BiPotPotential Specifies the potential for WE2. (inherited from Method)
Public field CellOnAfterMeasurement Enable/disable cell after measurement (inherited from Method)
Public field ConcentrationUnit The label for the unit of the analyte's concentration. This value is not used for calculations. (inherited from Method)
Public field ConditioningPotential Conditioning Potential (inherited from Method)
Public field ConditioningTime Conditioning Duration (inherited from Method)
Public field Current Current during measurement (Potentiometry). The applicable range of the potential is -2 to +2 * current range.
Public field DepositionPotential Deposition Potential (inherited from Method)
Public field DepositionTime Deposition Duration (inherited from Method)
Public field EquilibrationTime Duration (inherited from Method)
Public field IntervalTime Time between two measurements. (inherited from TimeMethod)
Public field MinPeakHeight Determines the minimum peak height. Peaks lower than this value are neglected. (inherited from Method)
Public field MinPeakWidth Determines the minimum peak width. Peaks width a lower width may not be detected. (inherited from Method)
Public field mux_delay Delay before switching to the next multiplexer channel.
Public field MuxMethod Defines the way the multiplexer is used.
  • 0 = measure channels sequentially
  • 1 = measure channels alternatingly
(inherited from Method)
Public field PeakOverlap Is used when two peaks are very close to each other. If the peak separation is less than the specified value, a single baseline is used for the two overlapping peaks. If each peak should have its own baseline, specify a value of 0. (inherited from Method)
Public field PeakWindow Is used to identify which component corresponds to which peak. Peaks must be within the peak window. (inherited from Method)
Public field Potential Potential during measurement (AmperometricDetection) or applied before pulse is given PulsedAmpDetection. The applicable range of the potential is -2 V to +2 V. (inherited from TimeMethod)
Public field Ranging Ranging information (inherited from Method)
Public field Reaction Defines the type of reaction, used for analysis
  • 1 = Reduction
  • 2 = Oxidation
(inherited from TimeMethod)
Public field RecordAux Auxiliary channel to record (inherited from Method)
Public field Replications Number of replications (inherited from TimeMethod)
Public field Sample Description of the measured sample. (inherited from Method)
Public field Sensor Description of the sensor used. (inherited from Method)
Public field Signal
  • 1 = DC_Current
  • 2 = Peak
If dc-current is specified, stationary dc-levels are searched. Specify 'Peak' when the current versus time plots will show peaks. (inherited from TimeMethod)
Public field SmoothLevel The smoothlevel to be used.
  • 0 = no smooth
  • 1 = 5 points
  • 2 = 9 points
  • 3 = 15 points
  • 4 = 24 points
(inherited from Method)
Public field Standard The concentrations of the analyte, used for analysis. (inherited from TimeMethod)
Public field StandbyPotential Stand by Potential (inherited from Method)
Public field UseMuxChannel Specifies channels used for this method. (inherited from Method)
Public field UseStirrer True if a stirrer is being used. (inherited from Method)
Public field ViewBottom The lowest value on the Y axis of the plot. (inherited from Method)
Public field ViewLeft The lowest value on the X axis of the plot. (inherited from Method)
Public field ViewRight The highest value on the X axis of the plot. (inherited from Method)
Public field ViewTop The highest value on the Y axis of the plot. (inherited from Method)
Public field XUnit Unit for X axis when using this method. (inherited from Method)
Public field YUnit Default unit for Y axis when using this method. (inherited from Method)