Home Accessories Redox.me – Spectro EFC Flow Cell Attachment
Redox.me – Spectro EFC Flow Cell Attachment
Use SPE holder under flow conditions using UV-VIS-NIR
- Couple Spectro EFC Flow cell attachment directly to a light source and spectrometer
- Variant for aqueous and organic solvent based experiments
- Scandinavian Design
Description
This is a multi-purpose Spectro-EFC Cell Attachment designed to be coupled with a light source and spectrometer (UV-vis-NIR) via bifurcated optical fiber. It enables obtaining electrochemical and spectroscopic information from the Screen-Printed Electrodes (SPE), where variations in the applied potential to working electrode induce changes in the observed reflection spectrum.
Applied curved optical collimating lens is to be connected with a bifurcated fiber (not included in the set) which has two fibers side-by-side in the common end and breaks out into two legs at the other end (i.e. light source and spectrometer).
- The lens is 5 mm in diameter, has a focal length of 10 mm, and wavelength range of 185-2500 nm.
- The distance between the lens and the surface of SPE is adjustable in a range of 15 to 20 mm, resulting in a spot size range of approximately 3 to 1.5 mm, respectively.
- The light spot is placed in the middle of the SPE sensor width.
The assembled set consisting of Screen-Printed Electrode Holder and Spectro-EFC Cell Attachment. The attachment elements are constructed with materials that are chemically resistive to a wide range of electrolytes (PEEK, PFA/ETFE). The Spectro-EFC Cell Attachment well fits aqueous (EPDM O-Rings) and organic solvent (FFKM O-Rings) electrolyte requirements.
Application note
This spectroelectrochemical set is used to study the relation between absorbance/reflectance and electrochemical potential. It enables real-time monitoring of the optical change at the surface of the working electrode. It also enables in-situ spectral acquisition for detection, identification, and characterization of short-lived electrochemically-generated species/intermediates, resulting in a detailed investigation of the mechanistic pathways of redox processes.
The Spectro-EFC Cell Attachment consists of two main parts: the chamber and the base which is installed on the guide rails of the Screen-Printed Electrode Holder. In the flow mode, the tubing is typically connected to the peristaltic pump, while in the static (stagnant) mode the cell attachment can be filled up using a syringe (neither the pump nor the syringe are included in the set).
Specification
- tubing size: 1/16″ OD x .040″ ID (1.6mm OD x 1.0mm ID)
- quartz window diameter: 10 mm
- quartz window thickness: 1 mm
- fiber connector: SMA 905, 6.35 mm ferrule
Intrastat data
- HS Code: 90275000
- Country of Origin: Sweden
- NET weight: 50 g (attachment only), 100 g (attachment with SPE holder)
Product includes
- 1 x Raman EC flow chamber with fittings
- 1 x collimating lens with SMA 905 optical fiber connector
- 1 x quartz window
- 1 x base
- 1 x set of O-Rings
- 1 x set of screws
- Optional: 1 x Screen-Printed Electrode Holder
Specifications
-
Weight0.1 kg
-
Dimensions75 × 54 × 19 cm
-
-
-
-
-